The IEC standard corresponding to GB/T3836-2021 standard

SINO Testing Services

| 2022-06-27|Return

With the release and implementation of the new version of the national standard GB/T3836-2021, domestic explosion-proof standards have further aligned with international explosion-proof standards. The new version of the national explosion-proof standard combines the original GB12476 and GB25286 standards, covering various aspects such as design, manufacturing, inspection, selection, installation, inspection, maintenance, repair, and site classification of equipment used in explosive environments. It adopts a segmented standard form, including but not limited to the following parts.

GB/T 3836.1-2021 Explosive Atmosphere Part 1: General Requirements for Equipment

Corresponding IEC standards: IEC 60079-0: 2017 Explosive Atmosphere Part 0: General Requirements for Equipment

GB/T 3836.2-2021 Explosive Atmosphere Part 2: Equipment Protected by Flameproof Enclosures "d"

Corresponding IEC standards: IEC 60079-1: 2014 Explosive Environments Part 1: Equipment Protected by Explosion proof Enclosures "d"

GB/T 3836.3-2021 Explosive Atmosphere Part 3: Equipment Protected by Increased Safety Type "e"

Corresponding IEC standards: IEC 60079-7: 2015 Explosive Atmosphere Part 7: Equipment Protected by Increased Safety Type "e"

GB/T 3836.4-2021 Explosive Atmosphere Part 4: Equipment Protected by Intrinsic Safety Type "i"

Corresponding IEC standards: IEC 60079-11: 2011 Explosive Atmosphere Part 11: Equipment Protected by Intrinsic Safety Type "i"

GB/T 3836.5-2021 Explosive Atmosphere Part 5: Equipment Protected by Positive Pressure Housing "p"

Corresponding IEC standards: IEC 60079-2: 2014 Explosive Atmosphere Part 2: Equipment Protected by Positive Pressure Shell "p"

GB/T 3836.6-2017 Explosive Atmosphere Part 6: Equipment Protected by Liquid Immersion Type "O"

Corresponding IEC standards: IEC 60079-6: 2015 Explosive Atmosphere Part 6: Equipment Protected by Liquid Immersion Type "O"

GB/T 3836.7-2017 Explosive atmospheres - Part 7: Equipment protected by sand filled molds "q"

Corresponding IEC standards: IEC 60079-5: 2015 Explosive Atmosphere Part 5: Equipment protected by sand filled mold "q"

GB/T 3836.8-2021 Explosive Atmosphere Part 8: Equipment Protected by "n" Type

Corresponding IEC standards: IEC 60079-15: 2017 Explosive Atmosphere Part 15: Equipment Protected by "n" Type

GB/T 3836.9-2021 Explosive Atmosphere Part 9: Equipment Protected by Sealed Type "m"

Corresponding IEC standards: IEC 60079-18: 2014 Explosive Atmosphere Part 18: Equipment Protected by Sealed Type "m"

GB/T 3836.11-2017 Explosive Atmosphere Part 11: Classification Test Methods and Data for Characteristics of Gas and Vapor Substances

Corresponding IEC standards: IEC 60079-20-1: 2010 Explosive Atmosphere Part 2-1: Classification Test Methods and Data for Gas and Vapor Substances Characteristics

GB/T 3836.12-2019 Explosive Atmosphere Part 12: Test Methods for Characteristics of Combustible Dust Substances

Corresponding IEC standards: ISO/IEC 80079-20-2: 2016 Explosive Atmosphere Part 20-2: Material Characteristics Combustible Dust Test Method

GB/T 3836.13-2021 Explosive Atmosphere Part 13: Equipment Repair, Maintenance, Restoration and Modification

Corresponding IEC standards: IEC 60079-19: 2019 Explosive Environment Part 19: Repair, Maintenance, and Restoration of Equipment

GB 3836.14-2014 Explosive Atmosphere Part 14: Site Classification Explosive Gas Atmosphere

Corresponding IEC standards: IEC 60079-10-1: 2008 Explosive Atmosphere Part 10-1: Classification of Hazardous Areas Explosive Gas Atmosphere

GB/T 3836.15-2017 Explosive Atmosphere Part 15: Design, Selection and Installation of Electrical Installations

Corresponding IEC standards: IEC 60079-14: 2007 Explosive Atmosphere Part 14: Design, Selection, and Installation of Electrical Installations

GB/T 3836.16-2017 Explosive Atmosphere Part 16: Inspection and Maintenance of Electrical Installations

Corresponding IEC standards: IEC 60079-17: 2007 Explosive Atmosphere Part 16: Inspection and Maintenance of Electrical Installations

GB/T 3836.17-2019 Explosive Atmosphere Part 17: Equipment Protected by Positive Pressure Room "p" and Artificially Ventilated Room "v"

Corresponding IEC standards: IEC 60079-13: 2017 Explosive Atmosphere Part 13: Equipment Protected by Positive Pressure Room "p" and Artificially Ventilated Room "v"

GB/T 3836.18-2017 Explosive Atmosphere Part 18: Intrinsically Safe Electrical Systems

Corresponding IEC standards: IEC 60079-25: 2010 Explosive Atmosphere Part 25: Intrinsically Safe Electrical Systems








Related Recommendations
Contact us
0755-2102 2109
Add: 13F, Building C, Kangjia Guangming Technology Center, No. 288 Xingxin Road, Guangming District, Shenzhen
Follow us
Copyright: Shenzhen Zhongnuo Testing Technology Co., Ltd. 粵ICP備18004888號
Service Hotline
18924609560
點擊這里給我發消息 1354407946
點擊這里給我發消息 1354407946
主站蜘蛛池模板: 国产亚洲午夜精品a一区二区 | 欧美视频在线观看免费最新 | 美女大黄三级视频在线观看 | 美国一区二区三区 | 精品999视频 | www.欧美成人 | 天天干视频网站 | 久久国产夜色精品噜噜亚洲a | 欧美性猛交xxx猛交 欧美性猛交高清58 欧美性猛交一区二区三区精品 | 国产精品乳摇在线播放 | 一级片a级片 | 男女三级视频 | 欧美第一区 | 精品亚洲欧美中文字幕在线看 | 亚洲欧美18v中文字幕高清 | 亚洲好视频 | 青草青视频在线观看 | 日本黄色免费观看 | 在线免费观看韩国a视频 | 国产三级在线 | 99精品中文字幕 | 日韩在线三级视频 | 欧美手机在线 | 欧美中文字幕一区二区三区 | 亚洲国产精品日韩高清秒播 | 日本三级网址 | 日本最新免费不卡二区在线 | 欧美亚洲国产一区 | 日本精品久久久久护士 | 秋霞手机入口二日韩区 | 天天爽天天 | 欧美日韩中文字幕 | 亚洲三级视频在线观看 | 日本免费一区二区三区中文字幕 | 三级在线观看视频 | 亚洲一区毛片 | 人九九精品 | 国产裸体美女视频全黄 | 九九热在线免费视频 | 日本欧美小视频 | 99热这|